Retrotech DM-2A Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Messen, Testen & Steuern Retrotech DM-2A herunter. Retrotech DM-2A User's Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - User Guide

Retrotec Model DM-2A mark II Dual Channel Pressure GaugeUser Guide

Seite 2 - Revision History

2Retrotec Energy Innovations, Ltd.DM-2A Mark II 2008-02-22DM-2A Mark II Dual-Channel Pressure Gauge User Manual1: Getting Started

Seite 3

Retrotec Energy Innovations, Ltd.3DM-2A Mark II 2008-02-22Section 1Getting StartedBefore you can begin using your new DM-2A mark II gauge, there are

Seite 4

4Retrotec Energy Innovations, Ltd.DM-2A Mark II 2008-02-222. Install the batteries according to the orientation symbols on the circuit panel.3. Re

Seite 5

Retrotec Energy Innovations, Ltd.5DM-2A Mark II 2008-02-22 Under typical operation, the DM-2A will operate for many hours on a set of fully charged

Seite 6

6Retrotec Energy Innovations, Ltd.DM-2A Mark II 2008-02-22 Your gauge will charge while turned off and while external power is available either from

Seite 7 - Table of Contents

Retrotec Energy Innovations, Ltd.7DM-2A Mark II 2008-02-22 The following list explains what each of the information labels printed around the perim

Seite 8 - Appendix C

8Retrotec Energy Innovations, Ltd.DM-2A Mark II 2008-02-22The keys labeled 0 through 9 and the decimal point can be used for inputting values when n

Seite 9

Retrotec Energy Innovations, Ltd.9DM-2A Mark II 2008-02-22• Velocity Displays the air velocity. This mode requires that a pitot tube be installed.

Seite 10 - 1: Getting Started

10Retrotec Energy Innovations, Ltd.DM-2A Mark II 2008-02-22 autO ZeRO Press the autO ZeRO keypad button to turn the automatic zeroing function on

Seite 11 - Getting Started

Retrotec Energy Innovations, Ltd.11DM-2A Mark II 2008-02-22 On / Off, BaCkligHt Pressing this button once while the gauge is off turns it on and di

Seite 12 - Checking Battery Health

Revision HistoryJan 29, 2008 0.00 Mark II, JeffJan 29, 2008 0.01 Colin copied to Word 2003 and edited it. Jan 31, 2008 0.02 Joe copied it to Word 2004

Seite 13 - AC Power Adapter

12Retrotec Energy Innovations, Ltd.DM-2A Mark II 2008-02-22NOTESDM-2A Mark II Dual-Channel Pressure Gauge User Manual1: Getting Started

Seite 14 - Viewing the Display Screen

Retrotec Energy Innovations, Ltd.13DM-2A Mark II 2008-02-22Section 2Working with the Setup ScreenIf you’re preparing your DM-2A mark II gauge for fir

Seite 15 - Using the Keypad Buttons

14Retrotec Energy Innovations, Ltd.DM-2A Mark II 2008-02-224. Press the enteR, (Left), and/or (Right) keypad buttons to display the Enable/Disa

Seite 16

Retrotec Energy Innovations, Ltd.15DM-2A Mark II 2008-02-227. Device ranges and/or configurations can also be custom-configured if needed. For exampl

Seite 17

16Retrotec Energy Innovations, Ltd.DM-2A Mark II 2008-02-224. Press the enteR, (Left), and/or (Right) keypad buttons to view the Enable/Disable

Seite 18

Retrotec Energy Innovations, Ltd.17DM-2A Mark II 2008-02-22 To cancel an incorrectly entered value, press the exit keypad button. Any values you en

Seite 19

18Retrotec Energy Innovations, Ltd.DM-2A Mark II 2008-02-22 The Power Down feature affects normal operation during testing. Be certain to allow for

Seite 20

Retrotec Energy Innovations, Ltd.19DM-2A Mark II 2008-02-22European Decimal ConventionsUse the European decimal convention option to specify how who

Seite 21 - Working with the Setup Screen

20Retrotec Energy Innovations, Ltd.DM-2A Mark II 2008-02-22Sig FigsThe Significant Figures – or ‘Sig Figs’ – feature controls the number of significan

Seite 22 - DM-2A Mark II 2008-02-22

Retrotec Energy Innovations, Ltd.21DM-2A Mark II 2008-02-22In normal (forward) mode, your gauge will increase the fan speed in order to achieve high

Seite 23 - Enabling and Disabling Modes

Retrotec Energy Innovations, Ltd.iDM-2A Mark II Dual-Channel Pressure Gauge User ManualDM-2A Mark II 2008-02-22Retrotec Model DM-2A mark II Dual Cha

Seite 24

22Retrotec Energy Innovations, Ltd.DM-2A Mark II 2008-02-22NOTESDM-2A Mark II Dual-Channel Pressure Gauge User Manual2: Working with the Setup Scree

Seite 25 - Automatic Power Down

Retrotec Energy Innovations, Ltd.23DM-2A Mark II 2008-02-22Section 3Connecting Your Gauge to a FanConnecting your DM-2A mark II to your Retrotec doo

Seite 26 - Volume Units

24Retrotec Energy Innovations, Ltd.DM-2A Mark II 2008-02-22Let’s explore a typical connection procedure as a practical example. To set up the connec

Seite 27 - European Decimal Conventions

Retrotec Energy Innovations, Ltd.25DM-2A Mark II 2008-02-229. Pass the red pressure tube through the door panel or cloth to the other side of the d

Seite 28 - Reverse Mode

26Retrotec Energy Innovations, Ltd.DM-2A Mark II 2008-02-22NOTESDM-2A Mark II Dual-Channel Pressure Gauge User Manual3: Connecting Your Gauge

Seite 29

Retrotec Energy Innovations, Ltd.27DM-2A Mark II 2008-02-22Section 4Exploring Basic Test OperationsNow that your DM-2A mark II gauge and fan are pro

Seite 30

28Retrotec Energy Innovations, Ltd.DM-2A Mark II 2008-02-22Using Time Average3. The time averaging feature calculates the average pressure over a g

Seite 31 - Section 3

Retrotec Energy Innovations, Ltd.29DM-2A Mark II 2008-02-22 Using the Auto Zero feature consumes additional power that may be a consideration when

Seite 32 - 3: Connecting Your Gauge

30Retrotec Energy Innovations, Ltd.DM-2A Mark II 2008-02-226. While the Set Speed feature is active, the current speed of the fan will be displayed

Seite 33

Retrotec Energy Innovations, Ltd.31DM-2A Mark II 2008-02-229. Press the JOg/HOld keypad button again. Notice that Hold now appears at the top centr

Seite 34

iiRetrotec Energy Innovations, Ltd.DM-2A Mark II Dual-Channel Pressure Gauge User ManualDM-2A Mark II 2008-02-22Copyright © 2005-2008 Retrotec Energ

Seite 35 - Section 4

32Retrotec Energy Innovations, Ltd.DM-2A Mark II 2008-02-22 The Set Pressure feature will cannot be used in free-air tests. 13. For example, enter

Seite 36 - Using Auto Zero

Retrotec Energy Innovations, Ltd.33DM-2A Mark II 2008-02-22Section 5Using Advanced Configuration ModesThe DM-2A mark II gauge has several different pr

Seite 37 - Setting the Fan Speed

34Retrotec Energy Innovations, Ltd.DM-2A Mark II 2008-02-22Preset ConfigurationBy default, your DM-2A mark II gauge is set to use a preset unit measu

Seite 38 - Using Jog/Hold

Retrotec Energy Innovations, Ltd.35DM-2A Mark II 2008-02-22Using Range Configuration OptionsEach flow device – or fan – supports various flow restricto

Seite 39 - Setting the Pressure

36Retrotec Energy Innovations, Ltd.DM-2A Mark II 2008-02-22NOTESDM-2A Mark II Dual-Channel Pressure Gauge User Manual5: Advanced Modes

Seite 40 - 4: Basic Operations

Retrotec Energy Innovations, Ltd.37DM-2A Mark II 2008-02-22Appendix AConfiguring and Using the DM-2A for Specific StandardsDifferent unit measurement c

Seite 41 - Using Advanced Configuration

38Retrotec Energy Innovations, Ltd.DM-2A Mark II 2008-02-22To perform your CGSB 149.10 standards test procedure, follow these steps:1. Assess and m

Seite 42 - Preset Configuration

Retrotec Energy Innovations, Ltd.39DM-2A Mark II 2008-02-22To configure your DM-2A mark II gauge for the Canadian ecoEnergy requirements, apply these

Seite 43 - 5: Advanced Modes

40Retrotec Energy Innovations, Ltd.DM-2A Mark II 2008-02-22DS/EN 13829To configure your gauge for the Dansk Standard for thermal performance of build

Seite 44

Retrotec Energy Innovations, Ltd.41DM-2A Mark II 2008-02-227. Press the enteR keypad button and input either the Envelope Area or the Net Floor Are

Seite 45 - 2A for Specific Standards

Retrotec Energy Innovations, Ltd.iiiDM-2A Mark II Dual-Channel Pressure Gauge User ManualDM-2A Mark II 2008-02-22About Retrotec Energy InnovationsRe

Seite 46 - A: Specific Configurations

42Retrotec Energy Innovations, Ltd.DM-2A Mark II 2008-02-22NOTESDM-2A Mark II Dual-Channel Pressure Gauge User ManualA: Specific Configurations

Seite 47

Retrotec Energy Innovations, Ltd.43DM-2A Mark II 2008-02-22Appendix BGlossary of Terms and AbbreviationsAs you learn how to use your gauge and/or co

Seite 48 - DS/EN 13829

44Retrotec Energy Innovations, Ltd.DM-2A Mark II 2008-02-22• Flow Pressure The pressure difference between inside the fan (in the flow stream) and a

Seite 49

Retrotec Energy Innovations, Ltd.45DM-2A Mark II 2008-02-22Appendix CGetting Help With Your GaugeAs you become familiar with using your DM-2A mark I

Seite 50

46Retrotec Energy Innovations, Ltd.DM-2A Mark II 2008-02-223. Press the enteR keypad button to display the Enable/Disable Device screen showing a l

Seite 51 - Abbreviations

Retrotec Energy Innovations, Ltd.47DM-2A Mark II 2008-02-22Getting HelpIf you are unable to resolve a problem you’ve encountered or you suspect ther

Seite 52 - B: Glossary

48Retrotec Energy Innovations, Ltd.DM-2A Mark II 2008-02-22Warranty informationYour limited warranty covers defects in materials and workmanship in

Seite 53 - Getting Help With Your Gauge

Retrotec Energy Innovations, Ltd.49DM-2A Mark II 2008-02-22Warranty on Refurbished EquipmentThe limited warranty is for 180 days on all refurbished

Seite 54 - C: Getting Help

50Retrotec Energy Innovations, Ltd.DM-2A Mark II 2008-02-22Field Replacement/RepairMost defective parts are easily field-replaceable. This is the fas

Seite 56 - Warranty information

ivRetrotec Energy Innovations, Ltd.DM-2A Mark II Dual-Channel Pressure Gauge User ManualDM-2A Mark II 2008-02-22Energy loss testing is used for meas

Seite 58

Retrotec Energy Innovations, Ltd.vDM-2A Mark II Dual-Channel Pressure Gauge User ManualDM-2A Mark II 2008-02-22Table of ContentsSection 1Getting Sta

Seite 59

viRetrotec Energy Innovations, Ltd.DM-2A Mark II Dual-Channel Pressure Gauge User ManualDM-2A Mark II 2008-02-22Section 5Using Advanced Configuration

Seite 60

Retrotec Energy Innovations, Ltd.1DM-2A Mark II 2008-02-22Introducing the Retrotec DM-2A mark IICongratulations on the purchase of your new Retrotec

Kommentare zu diesen Handbüchern

Keine Kommentare